dc.description | Las infecciones del tracto urinario asociadas al catéter (CAUTI), pertenecen a las principales infecciones nosocomiales del mundo y han llevado al estudio extenso de estrategias para prevenirla, asà como la búsqueda de varios materiales con propiedades antimicrobianas, pero, pese a los estudios a muchos materiales, solo unos pocos tipos han entrado en uso clÃnico, lo que sigue siendo una problemática por resolver. El titanio y la plata tienen estudios con diferentes dispositivos médicos como implantes dentales y artÃculos ortopédicos que destacan sus propiedades antimicrobianas, asà como su biocompatibilidad con el cuerpo humano, por lo tanto, este proyecto evaluó las propiedades antimicrobianas a partir de nano pelÃculas creadas con distintos porcentajes de los metales mencionados anteriormente y los cuales se pretenden usar en catéteres urinarios con el fin de realizar nano recubrimientos que ayuden a prevenir las infecciones causadas por el uso de estos. Los recubrimientos que se lograron caracterizar morfológicamente para identificar su influencia en la respuesta de inhibición bacteriana, mediante el conteo de unidades formadoras de colonias (UFC/mL), se evaluó la actividad antimicrobiana que tiene con respecto a las bacterias Proteus mirabilis, Klebsiella pneumoniae y Escherichia coli. La pelÃcula que funciono mejor para E. coli fue la placa con el recubrimiento Ti/Ag y para Proteus fue la pelÃcula de Ti 270/ Ag90 | |
dc.description.abstract | Catheter-associated urinary tract infections (CAUTI) belong to the main nosocomial infections in the world and have given rise to the extensive study of various strategies to prevent infection as well as the search for a wide variety of materials with antimicrobial properties, however, despite the studies of a large number of materials, only a few types have entered clinical use, which continues to be a problem to be solved. Titanium and silver have studies with different medical devices such as dental implants and orthopedic articles that highlight their antimicrobial properties, as well as their biocompatibility with the human body, therefore, this project evaluated the antimicrobial properties from nano-films created with different percentages of the above mentioned metals and which are intended to be used in urinary catheters in order to make nano-coatings that help prevent infections caused by the use of these. The coatings were characterized morphologically to identify their influence on the bacterial inhibition response; the wettability of the films was also studied and subsequently associated with the adherence of bacteria and their respective response; microbiologically, by counting colony forming units (CFU/mL); and finally, the antimicrobial activity was evaluated in relation to the bacteria Proteus mirabilis, Klebsiella pneumoniae y Escherichia coli. The film that worked best for E. coli was the plate with the Ti/Ag coating and for Proteus it was the Ti 270/ Ag90 film | |
dc.format | application/pdf | |
dc.format.extent | 21 páginas | |
dc.identifier.citation | Perilla, A. F. D. la cruz. (2024). Influencia de la matriz de titanio para recubrimientos de plata en las propiedades antibacterianas presentes en dispositivos urinarios. Universidad Santigo de Cali. | |
dc.identifier.uri | https://repositorio.usc.edu.co/handle/20.500.12421/8386 | |
dc.language.iso | es | |
dc.publisher | Universidad Santiago de Cali | |
dc.pubplace.city | Cali | |
dc.pubplace.state | Valle del Cauca | |
dc.rights.acceso | Acceso abierto | |
dc.rights.cc | Reconocimiento 4.0 Internacional (CC BY 4.0) | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.source.institution | Universidad Santiago de Cali | |
dc.source.repository | Repositorio Institucional USC | |
dc.subject | Titanio | |
dc.subject | Plata | |
dc.subject | Nano-recubrimientos | |
dc.subject | Bio-compatibilidad | |
dc.subject | Inhibición bacteriana | |
dc.subject.keyword | Titanium | |
dc.subject.keyword | Silver | |
dc.subject.keyword | Nano-coatings | |
dc.subject.keyword | Bio-compatibility | |
dc.subject.keyword | Bacteria inhibition | |
dc.title | Influencia de la matriz de titanio para recubrimientos de plata en las propiedades antibacterianas presentes en dispositivos urinarios | |
dc.type | Thesis | |
dc.type | ArtÃculo |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Trabajo de Grado.pdf
- Size:
- 1.26 MB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Formato de Autorización.pdf
- Size:
- 664.46 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Constancia de Radicación.pdf
- Size:
- 154.79 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: