Comparación cronológica de la estabilidad dimensional de dos técnicas convencionales de impresión versus técnica modificada con polivinil siloxano

dc.contributor.advisorArana Gordillo, Luis Alfonso (Director)
dc.contributor.authorArias Morales, Paola Andrea
dc.contributor.authorGuerra Ruiz, Dayana Marcela
dc.creator.degreeTrabajo de Grado para optar al título de Odontólogo
dc.date.accessioned2020-08-26T19:49:19Z
dc.date.available2020-08-26T19:49:19Z
dc.date.issued2019
dc.descriptionEl propósito de este estudio fue comparar la estabilidad dimensional de las técnicas convencionales y técnica modificada para impresiones en silicona a través del tiempo. Para la realización del estudio se confecciono un modelo de acero inoxidable, el cual simulaba tres pilares con sus líneas de terminación, los tres pilares fueron de 10 mm en altura y 10 mm de ancho, la superficie oclusal plana, de forma cuadrada, con una línea terminal de 2 mm. Por cada tiempo de vaciado (inmediato, 8 y 24 horas) se realizaron 12 impresiones, 4 por cada técnica de impresión, un total de 36 impresiones. Se tomaron 6 medidas (mesiodistal, vestíbulo lingual) a cada pilar del modelo de yeso obtenidos de estas impresiones mediante un micrómetro digital para ser comparadas con las medidas del modelo maestro. Se realizó un análisis estadístico descriptivo con prueba t de student, y un análisis de varianza (ANOVA) para la comparación de las áreas con dos factores fijos, (Técnica de impresión y Tiempo de vaciado), posteriormente la prueba Tukey revelo diferencias significativas en las tres técnicas cuando se realizó el vaciado a las 8 horas con la técnica a paso y medio (P = 0,001); Dos pasos (P = 0,002), no se encontraron diferencias significativas para la técnica a un paso ; a las 24 horas se encontraron diferencias significativas en técnica paso y medio (P = 0,007), dos a pasos (P = 0,047), la técnica a un paso no se encontraron diferencias significativas y finalmente en el vaciado inmediato no se encontraron diferencias significativas en ninguna técnica. El objetivo de este estudio es determinar la estabilidad dimensional de las técnicas convencionales y técnica modificada para impresiones en silicona a través del tiempo.
dc.description.abstractThe purpose of this study was dimensional stability. To carry out the study a stainless steel model was confirmed, which simulated three pillars with their finishing lines, the three pillars are 10 mm in height and 10 mm in width, the flat occlusal surface, in square shape, with a 2 mm terminal line. For each moment of emptying (immediate, 8 and 24 hours) 12 impressions were made, 4 for each printing technique, a total of 36 impressions. Six measures (mesiodistal, lingual vestibule) were taken each of the pillars of the time model to see these impressions by means of a digital micrometer to be compared with the measures of the master model. A descriptive statistical analysis was made with student test, and an analysis of variance (ANOVA) for the comparison of the areas with two fixed factors, and the Tukey test. three techniques when the vacuum was performed at 8 hours with the step and a half technique (P = 0.001); Two steps (P = 0.002), no significant differences were found for the one-step technique; at 24 hours, significant differences were found in the step and medium technique (P = 0.007), two steps (P = 0.047), the one-step technique was not significantly related and finally no technique. He objective of this study is to determine the dimensional stability of conventional techniques and modified technique for silicone impressions over time.
dc.formatapplication/pdf
dc.format.extent47 páginas
dc.identifier.citation1. Arias Morales, Paola Andrea; Guerra Ruiz DM. Comparación cronológica de la estabilidad dimensional de dos técnicas convencionales de impresión versus técnica modificada con polivinil siloxano. Universidad Santiago de Cali; 2019.
dc.identifier.urihttps://repositorio.usc.edu.co/handle/20.500.12421/3905
dc.language.isoes
dc.publisherUniversidad Santiago de Cali
dc.publisher.facultyFacultad de Salud
dc.publisher.programOdontología
dc.pubplace.cityCali
dc.pubplace.stateValle del Cauca
dc.rights.accesoAcceso Abierto
dc.rights.ccReconocimiento 4.0 Internacional (CC BY 4.0)
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.source.institutionUniversidad Santiago de Cali
dc.source.repositoryRepositorio Institucional USC
dc.subjectTécnicas de Impresión
dc.subjectSilicona de Adición
dc.subjectEstabilidad Dimensional
dc.subjectPolivinil siloxano
dc.titleComparación cronológica de la estabilidad dimensional de dos técnicas convencionales de impresión versus técnica modificada con polivinil siloxano
dc.typeThesis
dc.type.spaTrabajo de Grado

Files

Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Acta.pdf
Size:
690.14 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Formato de Autorización.pdf
Size:
581.91 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Trabajo de Grado.pdf
Size:
1.2 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections