Design and validation of a prototype to calibrate the pressure variable in tonometry

dc.contributor.authorPineda Zapata, Uriel
dc.contributor.authorDaza Fernández, Juan Fernando
dc.date.accessioned2025-07-09T21:00:20Z
dc.date.available2025-07-09T21:00:20Z
dc.date.issued2021
dc.description.abstractThis paper corresponds to the results of an experimental research that to led to the design of a useful prototype for quality control of measurements in the field of tonometry to diagnose and check glaucoma. All tonometry techniques are based on Goldmann´s tonometers (GT) and the Imbert-Fick principle. Taking into account the principles and techniques of industrial metrology, the prototype could be used as a standard to calibrate the pressure readings of this class of tonometers. The developed protoype eliminates the indirect measurement that is required with current standards and facilitates a greater control of the sources of error in the measurement. The model is based on the integration of a sensor to a hydraulic model to measure pressures from 0 to 80 mmHg range, whose precision was validated through R&R studies. The precision of the prototype was validated according to the Rigel UNI-SIM standard and was complemented by calibrating 15 tonometers.
dc.identifier.citationCastañeda-Morales, A., & Cuevas-Arenas, H. (2021). Between educating and perverting customs: Beginnings of the cinematographic show in valle del Cauca-Colombia (1910-1930). Cases of Cali and Buga. HiSTOReLo, 13(26), 105–132. https://doi.org/10.15446/HISTORELO.V13N26.85447 Pineda-Zapata, U., & Daza-Fernández, J. F. (2021). Design and validation of a prototype to calibrate the pressure variable in tonometry. DYNA (Colombia), 88(218), 185–193. https://doi.org/10.15446/DYNA.V88N218.91715
dc.identifier.issn00127353
dc.identifier.urihttps://repositorio.usc.edu.co/handle/20.500.12421/7328
dc.language.isoen
dc.subjectcalibration
dc.subjectmetrology
dc.subjecttonometry
dc.subjectuncertainty in measurement
dc.titleDesign and validation of a prototype to calibrate the pressure variable in tonometry
dc.title.alternativeDiseño y validación de un prototipo para calibrar la variable presión en tonometría
dc.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ArtĂ­culo.pdf
Size:
798.08 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: