A low-complexity PPG pulse detection method for accurate estimation of the pulse rate variability (PRV) during sudden decreases in the signal amplitude

dc.contributor.authorArgüello Prada, Erick Javier
dc.contributor.authorParedes Higinio, Alejandro
dc.date.accessioned2020-10-23T22:21:27Z
dc.date.available2020-10-23T22:21:27Z
dc.date.issued2020-03-26
dc.description.abstractBackground: One of the biggest obstacles to reliable pulse rate variability (PRV) analysis is the erroneous detection of photoplethysmographic (PPG) pulses. Among all the disturbances that may hinder pulse detection, the ripples appearing at the smooth segments of the PPG signal can become a serious problem when the amplitude of the signal decreases considerably. Objective: To present a low-complexity PPG pulse detection method for reliable PRV estimation under conditions in which a sudden decrease in the amplitude of the PPG signal can be expected. Approach: 2-min ECG and PPG data (sampling rate at 500 Hz) were obtained from thirty healthy subjects, who were asked to take a deep inspiration to provoke a sudden amplitude decrease (SAD) of the PPG signal. After introducing a new parameter denoted as C, through which it is possible to jump over the ripples hindering the accurate detection of the systolic peaks, 500 Hz-sampled PPG recordings were down-sampled (400, 300, 200 and 100 Hz) to investigate the effect of the sampling rate on pulse detection. For ECG recordings, automatic R-peak detection was performed by the Pan and Tompkins (PT) algorithm, whereas PPG pulse detection was performed by the well-known maximum of the first derivative (M1D) and the proposed method, once the C-value for best detection results on 500 Hz-sampled PPG recordings was found. The agreement between heart rate variability (HRV) and PRVs estimated from each pulse detection method was assessed and the correlation between HRV and PRV-derived indexes was computed for comparison. Main results: The proposed method can perform well on PPG-SAD segments, provided that the proper value of the parameter C is used. Moreover, a good agreement between HRV and PRV series, as well as lower relative errors and higher correlation coefficients between HRV and PRV indexes, were achieved by the proposed pulse detection method during SADs. Significance: Results show that the proposed method can dynamically adapt to circumstances in which a decrease in the amplitude of the PPG signal can be expected, providing continuous systolic peak detection and reliable PRV estimation under those conditions. However, more extensive testing under a wide range of conditions is needed to perform a more rigorous validation.en_US
dc.identifier.issn0967-3334
dc.identifier.urihttp://repositorio.usc.edu.co/handle/20.500.12421/4523
dc.language.isoenen_US
dc.publisherInstitute of Physics Publishingen_US
dc.subjectAutonomic balanceen_US
dc.subjectNoise contaminationen_US
dc.subjectPhotoplethysmographyen_US
dc.subjectPulse detectionen_US
dc.subjectPulse rate variability (prv)en_US
dc.subjectSudden amplitude decreaseen_US
dc.titleA low-complexity PPG pulse detection method for accurate estimation of the pulse rate variability (PRV) during sudden decreases in the signal amplitudeen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
A low-complexity PPG pulse detection method for accurate estimation.png
Size:
51.33 KB
Format:
Portable Network Graphics
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: